Comprehensive Building Defect Assessment TFG
Conditional Assessment
Comprehensive Building Defect Assessment TFG
Comprehensive building condition assessment , identifying construction defects and providing tailored repair recommendations with BOQ and tender documents for contractor assignment.
Location
Business Bay, Dubai
Overview
Super Arc Consultant LLC was commissioned to assess and identify the root cause of construction defects at a Hotel in Business Bay, Dubai. The defects, particularly in wet areas of various apartments, resulted in the appearance of efflorescence—salt deposits caused by water seepage through building surfaces. Despite previous attempts by the facility management to repair these issues, the seepage reoccurred, requiring a comprehensive assessment and solution.
Our team was tasked with conducting a thorough investigation, determining the underlying causes, and providing a detailed comprehensive building condition assessment report along with recommendations. Additionally, we prepared a Bill of Quantities (BOQ) and tender documents to enable the client to assign a contractor for the necessary remedial works.
Scope of Work
Visual Inspection and CategorizationA visual inspection of the affected apartments was carried out, during which defects were categorized into three levels based on severity: Category 1: No visible signs of seepage. Category 2: Moderate efflorescence and wall discoloration, with signs of moisture damage extending up to 20cm. Category 3: Severe efflorescence and wall discoloration, with damage extending up to 40cm. Category 3: Severe water seepage was noted, particularly due to faulty waterproofing systems and improper tile grout application, allowing water to travel between rooms.
Selection of Apartments for Detailed InvestigationFrom each defect category, one representative apartment was selected for further investigation, where tiles, sanitary fixtures, and waterproofing systems were dismantled to expose the raw materials and plumbing systems.
Non-Destructive and Destructive TestingTesting was conducted in the selected apartments to identify potential causes of the seepage. This included inspecting the waterproofing systems, plumbing connections, and construction materials.
Project Highlights
Findings:
01Category 1No significant water leakage was observed. However, issues with the improper installation of the waterproofing system at the threshold were noted.
02Category 2Water saturation was observed under the tiles, caused by poor sealing of the floor trap system and inadequate waterproofing at the threshold.
03Category 3Severe water seepage was noted, particularly due to faulty waterproofing systems and improper tile grout application, allowing water to travel between rooms.
Outcome
Recommendations and Remedial Measures
Based on the detailed findings from the comprehensive building condition assessment report, our team provided a set of recommendations to rectify the identified issues.
A comprehensive Bill of Quantities (BOQ) and tender documentation were prepared to guide the client in appointing a qualified contractor to carry out the remedial works. These documents include detailed specifications for materials, labor, and timelines, ensuring that all required repairs are addressed effectively and efficiently.
The project involves a comprehensive Structural and Hydrological Inspection to address the rising ground water level challenges. This includes field and laboratory testing, defect mapping, and…
Focusing on the distressed basement, we identified the root cause and provided a detailed roadmap for effective repairs. Our intervention not only resolved the long-standing issue…